Torpedo Heater, MASTER HEATER 165 BTU. |
 Click to view larger image
|
 |
|
Master Heaters B165DT
Kerosene/Diesel
Premium Forced Air Heaters,
Working Area 3900 sq ft,
Output Power: 165000 Btu/h
Features:
|
|
The choice for all types of industrial, commercial, and agricultural applications |
|
|
Built-in thermostat maintains set temperature and saves fuel |
|
|
Approved for outdoor use |
Heaters Help
If you do not know how much BTU you need to heat your space a simple formula can be followed:
1. Figure cubic square feet of space to be heated
Length x width x height Example: 50' long x 30' wide x 15' high= 22,500 cubic square foot of space
2. What is the average temperature outside?
This could be approx Example: outside temp is 15 degrees
3. What do you want the temperature to be in the building?
Example: 55 degrees
4. .The heat rise is (55 degrees inside - 15 degrees outside) = 40 degrees.
5. Multiply the cubic square foot by the heat rise.
22,500 x 40 degrees =900,000
6. Multiply by .133
.133 x 900,000 = 119,000 or approx 120,000 BTU./HR needed to heat the building
A Sample Heating chart
|
Temperature Rise |
| |
20 degrees |
30 Degrees |
40 Degrees |
50 Degrees |
| Total Cubic Feet |
|
|
|
|
| 5,000 cubic ft |
15,000 BTU |
20,000 BTU |
27,000 BTU |
34,000 BTU |
| 7,000 cubic ft |
19,000 BTU |
28,000 BTU |
38,000 BTU |
47,000 BTU |
| 10,000 cubic ft |
27,000 BTU |
40,000 BTU |
54,000 BTU |
54,000 BTU |
| 15,000 cubic ft. |
40,000 BTU |
60,000 BTU |
80,000 BTU |
100,000 BTU |
| 20,000 cubic ft |
54,000 BTU |
80,000 BTU |
107,000 BTU |
133,000 BTU |
| 30,000 cubic ft. |
80,000 BTU |
120,000 BTU |
160,000 BTU |
200,000 BTU |
| 50,000 cubic ft. |
133,000 BTU |
200,000 BTU |
266,000 BTU |
333,000 BTU |
|
|
|
|
|
|
|